Abstract

Window condition is one of the major factors of ventilation in office buildings. The study aimed at evaluating the natural ventilation in Senate buildings of selected Universities in South-West Nigeria. The study employed the use of questionnaires survey to solicit information on subjective feelings of the occupants on the effects of thermal opening and thermal comfort in Senate buildings offices. Direct observation was carried out to obtain information on the physical characteristics of the selected buildings. Limited research has been recorded on the study of occupants’ feelings in buildings in relation to openings in buildings. Based on the survey results, it was found that 34.0% of the windows were casement type, 30.0 % were projected 25.5% were sliding; while 9.5% were the louvred type. The study showed that 73.8% of the respondents preferred the casement window type because of its easiness in operation to other window types and improved thermal comfort on occupants. The study concluded that with adequate sizes, casement window type is the best in ameliorating the effect of thermal discomfort in Senate Buildings.

Keywords

References

  • Adebamowo, M. A. (2004). Study of thermal comfort characteristics in some residential buildings designed by Architects in Lagos. Building Quarterly , 2(4), 37-41.
  • Adunola, A. O. (2006). A study of thermal Comfort in Naturally Ventilated Residential Buildings in Olubadan Estate. Ibadan. An unpublished work for the Degree of Master of philosophy at the Obafemi Awolowo University (OAU), Ile –Ife, Nigeria.
  • Ayinla, A. K. (2011). Effects of Natural Ventilation on Residents’ Comfort in the Houses of the Traditional Core of Ogbomoso, Nigeria. An unpublished work for the Degree of Master of philosophy at the Obafemi Awolowo University (OAU), Ile –Ife, Nigeria.
  • Ayinla, A., Adeniyi, S. & Okeyinka, Y. (2013). Bio-Climatic Characteristics of Residential Building Types in the Traditional Core of Ogbomoso, South West Nigeria International Journal of Science, Environment ISSN 2278-3687 (O) and Technology , 2(6), 1462–1478.
  • ANSI/ASHARE. (2009). Standard 62.1, Ventilation for Acceptable Indoor Air Quality, Ashare. Inc. Atlanta, GA U.S.A.
  • Atkinson, J., Chartier, Y. & Pessoa-Silva, C. L. (2009). Natural Ventilation for Infection Control in Health – Care settings. Geneva: World Health Organization.
  • Awbi, H. B. (2003). Ventilation of buildings. 2nd ed. New York: Taylor & Francis.
  • Bluyssen, P. M., de Oliveira Fernandes, E., Groes, L., Clausen, G. H., Fanger, P. O., Valbjorn, O., Bernard, C. A. & Roulet, C. A. (1996). European indoor air quality audit project to optimize indoor air quality and energy consumption in office building: Indoor air Journal , 6, 221-338.
  • Chen, Q. (1996). Prediction of room air motion by Reynolds-stress models. Building and Environment, 31(3), 233–244.
  • Etheridge, D. & Sandberg, M. (1996). UK: John Wiley & Sons.
  • Fajobi, Kofoworola Joseph. (2004). A design proposal for Senate Building for Bowen University Iwo, Osun. Department of Architecture LAUTECH, Ogbomoso.
  • Frej, A. (2005). Green Office Buildings: A Practical Guide to Development. The Urban Land Institute, Washington, D. C, 4–8.
  • Iannone, F. (1999). Natural Ventilation and Sustainability: Designing with Computational Fluid Dynamics. Dipartimento di Architettura e Urbanistica – Politecnico di Bari Via Orabona, 4–70125.
  • Iannone, F. (1999). Displacement Natural Ventilation Systems Design in large rooms, Simplified models and Numerical evaluation for architectural design. Ancona University.
  • Nielsen, P. V. (1974). PhD thesis Denmark: Technical University of Denmark. Flow in air-conditioned rooms — model experiments and numerical solutions of the flow equations.

Downloads

No downloads have been recorded for this article yet. Figures appear here once readers begin downloading the full text.

How to Cite

A, A. C., Kunle, A. A., & Oluwole, A. (2018). Evaluating the Perception of Ventilation for Thermal Comfort in Senate Buildings: A Case of Nigeria Universities. Journal of Education and Vocational Research, 9(1), 1-9. https://doi.org/10.22610/jevr.v9i1.2556

Share this article

Section

Research Paper

Published

2018-11-30

Submissions

Have research to publish? Journal of Education and Vocational Research welcomes submissions.

Make a Submission